Best Victron Energy products in the Battery accessories category
On this page you'll find a ranking of the best Victron Energy products in this category. To give you a quick overview, we've already ranked the most important information about the products for you.
1. Victron Energy Current Transformer CTR110000500 Battery monitoring
The Victron current transformer 100 A:50 mA is an extension for the MultiPlus-II / MultiGrid-II series. This transformer allows for the implementation of the PowerControl and PowerAssist functions, as well as optimizing self-consumption with external power measurement.
Features
- For MultiPlus-II and MultiGrid-II series
- Cable length: 1 m
- Max. current: 32 A
- Easy installation via plug connection
PowerControl – Optimizing power supply with limited AC
The MultiPlus-II / MultiGrid-II can deliver a very high charging current. This means a significant load on the AC supply or generator. For this reason, a maximum current can be set. The MultiPlus-II then takes into account the existing consumption and only uses the remaining available current for battery charging.
PowerAssist – Extended usage options for generator or shore connection: the "support" function
With this function, the PowerControl principle gains a new dimension, as the MultiPlus-II can support an insufficient alternative source. Load peaks often occur only for a limited time. In such cases, the MultiPlus-II ensures that inadequate AC grid power or generator power is immediately compensated by energy from the battery. If the load is reduced, meaning consumers are turned off, the then sufficiently available energy can be used to charge the batteries.
Scope of delivery:
1x Victron Energy current transformer for MultiPlus-II 1 m (CTR110000500).

2. Victron Energy Smart Battery Protect 12/24V--220A BPR122022000 Battery Isolator
The Victron Battery-Protect BP-220 disconnects the battery from less important consumers before it is fully discharged, which could cause damage, or before it no longer has enough energy to start the engine. Additionally, the BP series features overvoltage protection, which disconnects the load at 16 V or 32 V battery voltage, safeguarding against damage. The BP supports AGM, lead-acid, gel, and lithium batteries.
Six different disconnect thresholds are adjustable. The Battery-Protect is highly flexible and can be set to various disconnect voltages. The following disconnect thresholds can be activated on the device: 10.5 V / 21 V, 10 V / 20 V, 9.5 V / 19 V, 11.25 V / 22.5 V, 11.5 V / 23 V, 11.8 V / 23.6 V. Additionally, there are different reconnection thresholds available for most disconnect thresholds. This makes the device the perfect protection for your battery, ensuring maximum lifespan, as most voltage converters or charge controllers do have undervoltage protection, but this typically activates at quite low values, usually around 10.5 V / 21 V. The higher the disconnect threshold, the longer you will enjoy your batteries, which are generally quite costly.
The selection of the disconnect threshold depends on the battery type, as different minimum battery voltages must be adhered to in order to avoid damaging the battery.

Victron Energy Smart Battery Protect 12/24V--220A BPR122022000 Battery Isolator
3. Victron Energy BCD 802 Battery coupler, 2 batteries 80A
Argo Diode Battery Coupler
Diode battery couplers are used to ensure a continuous DC power supply for critical devices, such as an electronic motor control system. With a diode battery coupler, two or more DC sources can be connected in parallel to supply the essential load. If one source fails, the power supply to the necessary load remains uninterrupted.

4. Victron Energy BCD 402 Battery coupler, 2 batteries 40A
Argo Diode Battery Coupler
Diode battery couplers are used to provide continuous DC power to supply critical equipment, such as an electronic engine control system. Using a diode battery coupler, two or more DC sources can be connected in parallel to supply the necessary load. If one source fails, the supply to the necessary load is not interrupted.

5. Victron Energy Batterie Anzeigetafel
Battery indicator panel with voltage sensor
The battery indicator panel shows the status of the battery. It is an accessory for the Blue Smart IP65 chargers.
With M8 ring terminals & 30Amp ATO fuse.
Suitable for 12 V lead-acid batteries (liquid electrolyte, GEL, AGM).

6. Victron Energy Shunt SHU500050100 Battery monitoring
The Victron Energy Shunt SHU500050100 is a high-quality accessory for battery monitoring that enables precise measurement of current flow in battery systems. With a maximum current of 500A and a voltage of 50mV, this shunt provides a reliable solution for monitoring and managing battery performance. It is particularly useful in applications where accurate monitoring of energy consumption and battery performance is required. The shunt is suitable for use in various battery systems and contributes to optimising energy efficiency. Its robust construction ensures a long lifespan and reliability, while the straightforward installation allows for quick integration into existing systems. The Victron Energy Shunt is therefore a valuable addition for anyone looking to effectively monitor their battery performance.
- Maximum current of 500A for precise measurements
- Voltage of 50mV for enhanced accuracy
- Robust construction for a long lifespan.

7. Victron Energy Cyrix-Li-Load CYR010120450 Battery monitoring
Cyrix Lithium BMS Battery Coupler
The Cyrix Battery Coupler is a high-performance microprocessor-controlled relay that can be used to protect Victron LiFePO4 batteries.
To prevent cell undervoltage, overvoltage, and overheating, all Victron LiFePO4 batteries feature an integrated cell balancing function. This function internally regulates the differences between the cells and informs the external BMS whether to disconnect or connect the charging or discharging process.
- Disconnecting the load in the event of imminent cell undervoltage
- Disconnecting or reducing the charging current in the event of imminent cell overvoltage, high temperature (>50°C), or low temperature (<0°C).
The core of this protection mechanism is the VE.Bus BMS or the Small BMS. However, the VE.Bus BMS can only directly instruct VE.Bus devices to interrupt charging or discharging. Other loads or chargers must be controlled externally. This also applies to the Small BMS, which cannot control VE.Bus devices.
To disconnect such loads or chargers, several Cyrix switches that can be controlled by the BMS are available.
The models differ in:
System voltage, load capacity, and whether a load or a charge should be controlled.
Here, Load is for controlling the load and Charge is for controlling the charge.
For more complex systems, it often makes sense to consult.

8. Victron Energy DIN35 Large ADA500180100 Mounting plate
The Victron Energy DIN35 Large Adapter (MPN ADA500180100) is designed for easy mounting of a device on a DIN rail.
The adapter is compatible with the following models:
- BlueSolar MPPT 75/10, 75/15 & 100/15
- Orion 110/120W
The rail adapter has the following dimensions: 105 x 11 x 12.5 mm
Included in the delivery:
2x Victron Energy DIN35 Large Adapters.

9. Victron Energy Argo
Similar to diode battery separation, FETs can simultaneously charge two or more batteries through an AC generator or a battery charger with a single output, without connecting the batteries to each other. Unlike diode battery separation, FET separation results in virtually no voltage loss. The voltage drop is less than 0.02 volts at low current and averages 0.1 volts at higher current levels.

10. Victron Energy Argofet 200-3, 3 batteries 200A
Argo FET Battery Separation
Similar to separation diodes, FET isolators allow for the simultaneous charging of two or more batteries through a generator or a charger connection without connecting the batteries to each other. Discharging the onboard battery does not lead to the simultaneous discharge of the starter battery. Unlike separation diodes, FET isolators have practically no voltage loss. The voltage drop is less than 0.02 volts at low currents and only 0.1 volts at higher currents. With the ARGO FET battery separation, no voltage increase is required. However, it is advisable to use short cable lengths and adequate cross-sections.
Generator Starting Excitation
Some types of generators require a DC voltage at the B+ terminal for starting excitation. On one hand, there is a direct cable connection between the battery and the generator. On the other hand, the separation diode prevents current backflow, which means the generator does not start. The new Argofet battery separation features a special current-limited connection for starting excitation when the generator is started.