Best Eltako products in the Energy monitors category

On this page you'll find a ranking of the best Eltako products in this category. To give you a quick overview, we've already ranked the most important information about the products for you.

1. Eltako Three-phase meter

Eltako Mobile Three-Phase Meter DSZ180CEE-16

Manufacturer: Eltako
Description: Mobile Three-Phase Meter MID calibrated 16A
Type: DSZ180CEE-16
Meter Type:
electronic
Rated Current (In): 10 A
Maximum Current (Imax): 80 A
Rated Voltage (Un) N-L: 230 V
Rated Voltage (Un) L-L: 400 V
Frequency: 50 Hz
Accuracy Class: B
Polarity: Four-Wire
Design: Direct Measurement
Energy Type: Active Power
Suitable for: Consumption
Reverse Lock: yes
Calibrated: yes
Approval: Measuring Instruments Directive
Display Type: digital
Width: 86 mm
Depth: 82 mm
Height: 180 mm
Interface Design: other
Number of Digits: 7
Protection Class (IP): IP54

Additional Details: Mobile three-phase meter with CEE plug 16A and CEE socket 16A. Suitable for indoor and outdoor use. Maximum current 16A, standby loss only 0.5 watts per path. Housing dimensions 180x86x82 mm, connection cable 1.5 m (including plug and socket). Accuracy class B (1%). This mobile three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of a maximum of only 0.5 watts of active power per path is not measured and not displayed. The starting current is 40 mA. The display can only be read with power supply. However, the consumption is stored non-volatile and is immediately displayed again after a power failure. The digital display has 7 digits. Up to 99999.99 kWh, two decimal places are displayed; from 100000.0 kWh, only one decimal place is shown. The power consumption is indicated by a bar that blinks 100 times per kWh on the display. EAN: 4010312501863.
 

2. Eltako DSZ15EN

Maximum current 3x80A, standby loss only 0.5 watts per path. Modular device for mounting on DIN rail EN 60715 TH35. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With S0 interface. The directly measuring three-phase energy meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 external conductors with currents up to 80A can be connected. The inrush current is 40 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. Power consumption is displayed with a bar that blinks 100 times per kWh. Standardly usable as a 2-tariff meter: by applying 230V to terminals E1/E2, it switches to a second tariff. To the right of the display are the MODE and SELECT buttons. 

3. Eltako MBusWandlerThree-phase meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. M-Bus converter three-phase meter with adjustable converter ratio and MID. Maximum current 3x5A, standby loss only 0.5 watts per path. Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rail. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With M-Bus interface. This three-phase meter measures active energy based on the currents flowing through the converters. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 converters can be connected with secondary currents up to 5A. The starting current is 10 mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a LED that blinks 10 times per kWh. To the right of the display is... 

Eltako MBusWandlerThree-phase meter MID calibrated
Energy monitors
CHF194.–

Eltako MBusWandlerThree-phase meter MID calibrated

4. Eltako Air

The sensor is mounted with its attachment magnet above the IR output of the meter and connected via its connection cable to the terminals Tx, Rx, GND, and +12V of the RS485 bus power meter data gateway FSDG14. 

5. Eltako DSZ15WD-3X5A MID

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is considered an administrative offense under §19. This is a transformer three-phase meter with adjustable transformer ratio and MID. Maximum current is 3x5A, with a standby loss of only 0.5 watts per path. It is a modular device for mounting on a DIN-EN 60715 TH35 rail. It occupies 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). Equipped with an S0 interface. This three-phase meter measures active energy based on the currents flowing through the transformers. The self-consumption of only a maximum of 0.5 watts active power per path is not measured or displayed. It can connect 1, 2, or 3 transformers with secondary currents up to 5A. The starting current is 10mA. The neutral connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. The power consumption is indicated by a bar that blinks 10 times per kWh on the display. 

6. Eltako MBus three-phase meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. M-Bus three-phase meter. Maximum current 3x80A, standby loss only 0.5 watts per path. Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rails. 4 division units = 70mm wide, 58mm deep. Accuracy class B (1%). With M-Bus interface. The directly measuring three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 external conductors with currents up to 80A can be connected. The starting current is 40mA. The N connection must be present. The 7-segment LC display can also be read twice within two weeks without power supply. Power consumption is indicated by a blinking LED that flashes 1000 times per kWh. It can also be used as a 2-tariff meter as standard. 

7. Eltako usRadio three-phase meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. RS485 bus radio three-phase meter. Maximum current 3x80A, standby loss only 0.8 watts on L1 and 0.5 watts each on L2 and L3. Accuracy class B (1%). With RS485 interface. The directly measuring three-phase meter measures the active energy based on the currents flowing between the inputs and outputs. The self-consumption of only a maximum of 0.8 watts or 0.5 watts active power per path is not measured and not displayed. 1, 2, or 3 external conductors with currents up to 80A can be connected. The starting current is 40 mA. Connections L1 and N must be present. Connection via an FBA14 to the Eltako RS485 bus with a 2-wire shielded bus line (e.g., telephone line). The meter reading and instantaneous power are transmitted to the bus - e.g., for forwarding to an external computer or the GFVS 3.0 software - and also via the FAM14 into the radio. 

8. Eltako DSZ14DRSZ-3x80A MID

Only calibrated meters are approved for electricity billing according to Section 25 of the German Calibration Act. Non-compliance is considered an administrative offense under Section 19. RS485 bus two-way three-phase meter. Maximum current 3x80A, standby loss only 0.8 watts on L1 and 0.5 watts each on L2 and L3. Rail-mounted device for installation on DIN-EN 60715 TH35 mounting rails in installation cabinets with protection class IP51. 4 division units = 70 mm wide, 58 mm deep. Accuracy class B (1%). With RS485 interface. The directly measuring three-phase meter measures active energy based on the currents flowing between the inputs and outputs. The self-consumption of only 0.8 watts or 0.5 watts active power per path is not measured and not displayed. The active energy is added depending on the sign. Positive power in the meter indicates energy consumption, while negative power indicates energy delivery. Energy measurement is net. If energy consumption (P positive) is greater than energy delivery (P negative), the meter reading increases to the right. If energy delivery is greater than energy consumption, the meter reading increases to the left. Energy consumption is indicated with a right arrow and energy delivery with a left arrow above the active bar on the display. 1, 2, or 3 external conductors with currents up to 80 A can be connected. The starting current is 40 mA. Connections L1 and N must be present. Connection via an FBA14 to the Eltako RS485 bus with a 2-wire shielded bus cable. The meter reading and instantaneous power are transmitted to the bus and also sent via the FAM14 into the radio network. It is necessary for the radio antenna module FAM14 to assign a device address as described in the operating manual. 

9. Eltako FGW14W-IP Gateway Top-hat rail

Eltako BUS Power Meter FGW14W-IP

Manufacturer: Eltako
Designation: BUS Power Meter
Type: FGW14W-IP
KNX Bus System: no
KNX Radio Bus System: no
Radio Bus
System: yes
LON Bus System: no
Powernet Bus System: no
Other Bus Systems: none
Bidirectional Radio: no
Design: RS-485
Mounting Type: DIN Rail
Width in Division Units: 1
Disassembly Protection: no
With LED Display: no
Updatable: no
Operating Voltage: 12 V
Voltage Type: DC
Power Consumption: 0.8 W
Protocol: other
Provider Dependent: no
Visualization: no
Web Server: no
Radio Interface: no
IR Interface: no
Protection Class (IP): IP20

The gateway with IP interface for the series 14 power meters over WLAN has a standby loss of only 0.8 watts. It is a modular device designed for mounting on DIN rail EN 60715 TH35. One division unit corresponds to 18 mm in width and 58 mm in depth. The gateway is only 1 division unit wide. For operation, the gateway must be integrated into a WLAN that uses the 2.4 GHz frequency band. The connection is made to the Eltako RS485 bus. Cross-wiring of the bus and power supply is done with a jumper. Operation is possible in conjunction with FAM14 or FTS14KS. The hold terminal is connected to the FAM14 or FTS14KS. The IP connection is made via WLAN. The gateway transmits data from any Eltako power meters on the RS485 bus via the MQTT protocol to an external MQTT broker. The data is encoded according to the EnOcean over IP format. Configurations and updates are carried out via the Eltako Connect app or through a web interface. A REST API is available through the online product page of the device.

EAN: 4010312327876.
 

10. Eltako Alternating current meter MID calibrated

Only calibrated meters are approved for electricity billing according to §25 of the German Calibration Act. Non-compliance is an administrative offense under §19. Maximum current is 65 A, with a standby loss of only 0.4 watts. This is a modular device for mounting on a DIN-EN 60715 TH35 rail. 1 modular unit = 18 mm wide, 58 mm deep. Accuracy class B (1%). Equipped with an S0 interface. This AC meter measures active energy based on the current flowing between the input and output. The self-consumption of only a maximum of 0.4 watts of active power is not measured and not displayed. One external conductor with a current of up to 65 A can be connected. The starting current is 40 mA. If a load exceeding 50% is expected, a ventilation distance of 1/2 modular unit must be maintained from adjacent devices. If necessary, use the spacer DS12. Two N terminals for secure cross-wiring of multiple meters. The 7-segment LC display can also be shown twice within two weeks without power supply.