Tensai Battery Enercig TN16500HP (Flat Top)

16500
Currently out of stock
Free shipping starting at 50.–

Product details

The only UL-certified 16500 cell in this format worldwide! Enercig (Tensai) TN16500HP Lithium-Ion (Flat Top) nominal capacity 800mAh min. capacity 750mAh nominal voltage 3.6V - 3.7V charge termination voltage 4.2V ± 0.05V discharge termination voltage 2.75V max. discharge current (constant) (20C) 16A flat positive terminal (Flat Top) protection electronics (PCB) none chemical composition LiCoO2 diameter 16.20 mm ± 0.10 mm height 50.15 mm ± 0.15 mm weight 33 g ± 1 g charging method CC-CV test results LygteInfo safety notes: Lithium cells should only be operated with protection electronics! Please note that lithium cells may only be used by qualified personnel. Improper handling or short circuits can lead to fire or explosion. Additional features: Lithium-ion batteries are thermally stable and do not suffer from memory effect. They operate on the basis of lithium and are characterized by a high energy density. Technical specifications for "Enercig (Tensai) TN16500HP Li-Ion 800mAh, 3.6V - 3.7V (Flat Top)" normal charging current 500mA/3h max. charging current 1000mA/1.5h operating temperature charging 0 °C - 45 °C operating temperature discharging -20 °C - 60 °C notes: Charging lithium-ion batteries requires a special charger that charges the batteries according to a specific charging method. (CCCV = constant current, constant voltage.) The batteries must not be charged beyond a voltage of 4.2 volts, as this poses a risk of fire and explosion. It is advantageous to charge the batteries only up to about 4.1 volts, as this significantly increases the lifespan or number of charge cycles (potentially up to doubling). Only lithium-ion chargers should be used for charging. However, cheap chargers sometimes have the disadvantage of not safely shutting off after the charging process is complete, but instead continue to charge the batteries with a small current, which can be dangerous.

Key specifications

Battery type
Li-Ion battery
Battery voltage
3.70 V
Battery type
Li-ion

General information

Item number
13106718
Manufacturer
Tensai
Category
Batteries
Manufacturer No.
AKT-100314
Release date
21.4.2020

Battery properties

Battery type
Li-Ion battery
Battery size
16500
Battery voltage
3.70 V
Battery type
Li-ion

Product dimensions

Weight
33 g

Ingredients and instructions for use

Ingredients
The only UL-certified 16500 cell in this format worldwide!Enercig (Tensai) TN16500HP Lithium-Ion (Flat Top)Nominal capacity (mAh)800mAhMin. Capacity (mAh)750mAhNominal Voltage (Volt)3.6V - 3.7VFinal Charge Voltage (Volt)4.2V ± 0.05VEntFinal Charge Voltage (Volt)2.75VMax. Discharge current (constant)(20C) 16APlus pole (structure)flat (flat top)Protection electronics (PCB)noneComposition (chemistry)LiCoO2Diameter (mm)16.20 mm ± 0.10 mmHeight (mm)50.15 mm ± 0.15 mmWeight (g)33 g ± 1 gCharging methodCC-CVSafety instructions:Lithium cells may only be operated with protective electronics!Please note that lithium cells may only be used by qualified persons.Incorrect handling or short-circuiting can lead to fire or explosion.other properties:Lithium-ion batteries are thermally stable and are not subject to a memory effect.they work on the basis of lithium and are characterised by a high energy density.technical data for "Enercig (Tensai) TN16500HP Li-Ion 800mAh, 3.6V - 3.7V (Flat Top) "Charging current normal500mA/3hMax. Charging current (Ampere)1000mA/1.5hOperating temperature charging0 °C - 45 °COperating temperature discharging-20 °C - 60 °CNotes:Charging lithium-ion batteries requires a special charger that charges the batteries using a special charging process. (CCCV = constant current, constant voltage.) The batteries must not be charged above a voltage of 4.2 volts, otherwise there is a risk of fire and explosion. It is advantageous to charge the batteries only up to approx. 4.1 volts, as this significantly increases the service life or number of charging cycles (possibly up to double). Only lithium-ion chargers may be used for charging. However, cheap chargers sometimes have the disadvantage that they do not switch off safely at the end of the charging process, but continue to charge the batteries with a small charging current, which can be dangerous. Please dispose of them as prescribed by law in the municipal collection centres or in the [usually green] containers provided for this purpose by retailers.

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Batteries» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • Tensai
    Not enough data
  • 1.Absina
    0 %
  • 1.AccuCell
    0 %
  • 1.Audisana
    0 %
  • 1.Blaupunkt
    0 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Tensai
    Not enough data
  • 1.Ansmann
    0 days
  • 1.Coast
    0 days
  • 1.Duracell
    0 days
  • 1.Energizer
    0 days

Return rate

How often is a product of this brand in the «Batteries» category returned?

Source: Digitec Galaxus
  • Tensai
    Not enough data
  • 1.Acconic
    0 %
  • 1.Arcas
    0 %
  • 1.Blaupunkt
    0 %
  • 1.FDK
    0 %
Source: Digitec Galaxus