Eaton EATO safety contactor

Delivered between Sat, 18.10. and Thu, 6.11.
free shipping

Product details

Safety contactor for motors and complete devices up to 170 A. Utilisation category: AC-1 for non-inductive or weakly inductive loads and resistance furnaces; AC-3 for squirrel cage motors, including starting and switching off while running; AC-4 for squirrel cage motors, including starting, counter-current braking, reversing, and inching. Connection technology includes screw terminals. Note: Also suitable for motors of efficiency class IE3; IE3-compatible devices are labelled with the logo on the packaging.

Description: This device features two electronically compatible microswitches (1 S + 1 Ö) and an auxiliary switch module permanently connected to the basic device (manual operation not possible).

Rated operating current AC-3 at 380 V and 400 V: Ie = 12 A. Rated operating current AC-1 conventional thermal current (3-pole, 50 - 60 Hz) open at 40 °C: Ith = Ie = 22 A; encapsulated: Ith = 18 A. Rated operating current AC-1 conventional thermal current (1-pole open): Ith = 50 A; encapsulated: Ith = 45 A.

Maximum rated operating power for three-phase motors (50 - 60 Hz) AC-3: 220 V 230 V: P = 3.5 kW; 380 V 400 V: P = 5.5 kW; 660 V 690 V: P = 6.5 kW. Maximum rated operating power for three-phase motors (50 - 60 Hz) AC-4: 220 V 230 V: P = 2 kW; 380 V 400 V: P = 3 kW; 660 V 690 V: P = 4.4 kW.

Contact configuration: S = NO contact: 2 S; NC = NC contact: 3 NC. Notes: Switching elements according to EN 50012, with mirror contact (not for microswitches). Current type: AC/DC, with AC actuation.

Key specifications

input voltage
3360 V
Scope of delivery
AC-3: Squirrel cage motors: StartingAC-4: Squirrel cage motors: StartingApplication: Power contactor for motorsComplete devices up to 170 AConnection technology: Screw terminalsCounter-current brakesNote: Also suitable for motors in efficiency class IE3Resistance furnacesSafety contactorSwitch off during the runTapUtilisation category: AC-1: Non-inductive or weakly inductive load
Output current type
AC/DC
Relay type
Power contactor
Item number
33815718

General information

Manufacturer
Eaton
Category
Relays
Manufacturer no.
191756
Release date
17.5.2023

Relay properties

Relay type
Power contactor
input voltage
3360 V
Output current type
AC/DC
Switching function
Opener
Number of openers
3 x

Smart home features

Smart Home
Not compatible

Voluntary climate contribution

CO₂-Emission
Climate contribution

Scope of delivery

Scope of delivery
AC-3: Squirrel cage motors: StartingAC-4: Squirrel cage motors: StartingApplication: Power contactor for motorsComplete devices up to 170 AConnection technology: Screw terminalsCounter-current brakesNote: Also suitable for motors in efficiency class IE3Resistance furnacesSafety contactorSwitch off during the runTapUtilisation category: AC-1: Non-inductive or weakly inductive load

30-day right of return
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Relays» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 3.ABB
    0.2 %
  • 3.Eltako
    0.2 %
  • 5.Eaton
    0.3 %
  • 6.Siemens
    0.5 %
  • 7.Schalk
    0.6 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Eaton
    Not enough data
  • 1.Shelly
    0 days
  • ABB
    Not enough data
  • Aqara
    Not enough data
  • Eltako
    Not enough data

Return rate

How often is a product of this brand in the «Relays» category returned?

Source: Digitec Galaxus
  • 3.Phoenix Contact
    1.2 %
  • 4.Shelly
    1.4 %
  • 5.Eaton
    1.9 %
  • 6.Hager
    2.4 %
  • 7.Metz Connect
    2.5 %
Source: Digitec Galaxus