Product details

Residual current circuit breaker according to DIN EN 61009-1 (VDE 0664-20) with QuickConnect terminal, up to 20 A at the feeder and up to 63 A at the feeder, blue test button and residual current indication. Simple individual removal from the phase busbar system. Suitable for retrofitting of additional equipment. Labeling option directly on the device.

Key specifications

Circuit breaker type
Fault current circuit breakerMiniature circuit breaker
Length
68 mm
Width
35 mm
mounting style
Top-hat rail
number of poles
2
Item number
20024725

General information

Manufacturer
Hager
Category
Residual-current device
Manufacturer no.
ADS916D
Release date
16.3.2022
Sales rank in Category Residual-current device
2 of 14692

Colour

Colour
BlueWhite
Exact colour description
BlueWhite

Circuit Breaker Features

Circuit breaker type
Fault current circuit breakerMiniature circuit breaker
mounting style
Top-hat rail
number of poles
2
Tripping characteristic
B
Rated current
16 A
Rated current
0.03 A
Rated voltage
240 V
voltage type
AC
Rated insulation voltage Ui
500 V
Residual current (rated differential current)
0.03 A
Protection type (IP code)
IP20

Origin

Country of origin
France

Voluntary climate contribution

CO₂-Emission
Climate contribution

Scope of delivery

Items per sales unit
1 Piece

Product dimensions

Length
68 mm
Width
35 mm
Height
94 mm
Weight
224 g

Package dimensions

Length
10 cm
Width
8 cm
Height
4 cm
Weight
216 g

30-day right of return if unopened
24 Months Warranty (Bring-in)
2 additional offers

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Siemens
    0 %
  • 4.Eaton
    0.2 %
  • 5.ABB
    0.3 %
  • 5.Hager
    0.3 %
  • 7.Steffen
    0.7 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Hager
    Not enough data
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Legrand
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 4.Legrand
    1.9 %
  • 5.Siemens
    2 %
  • 6.Schneider Electric
    2.1 %
  • 7.Eaton
    4.3 %
  • 8.Hager
    4.6 %
Source: Digitec Galaxus