Siemens RCD/MCB, 6 kA, 1P+N, Type A, 30 mA, B-Characteristic, In: 16 A, Un AC: 230 V. RCD/MCB for combined short-circuit protection and touch protection. Siemens' patented RCD/MCBs are an essential component of the SENTRON protection devices for electrical installations, enabling combined personal, fire, and line protection in a single device. In addition to detecting fault currents, they also provide reliable protection against short circuits and overloads thanks to the integrated overcurrent protection device. The Siemens RCD/MCBs, as a combination of residual current and circuit breakers, stand out primarily due to: 1. Increased operational safety and system availability thanks to the separate disconnection of the affected circuit. 2. Whether sinusoidal alternating fault currents or smooth direct fault currents - Siemens offers the suitable type for all requirements as well as special versions. 3. Reliable safety during installation thanks to the standard included gripping and touch protection. 4. Tool-free removal from the DIN rail or from the busbar connection through convenient sliding manual operation. 5. Clearly visible switching position indicator. 6. Data matrix code on the front of the device provides quick and easy access to all information regarding the RCD/MCB. 7. Be compliant with standards: The RCD/MCBs meet the requirements of DIN VDE. 8. Optimal technology for your safety - exclusively from Siemens. Siemens offers a comprehensive portfolio of protection, switching, measuring, and monitoring devices as well as distribution systems for safe and efficient electrical infrastructure in buildings and industry.
Circuit breaker type | Fault current circuit breaker |
Length | 77 mm |
Width | 36 mm |
number of poles | 1 |
Mounting type | Top-hat rail |
Item number | 8411127 |
Manufacturer | Siemens |
Category | Residual-current device |
Manufacturer no. | 5SU1356-6KK16 |
Release date | 20.4.2018 |
Sales rank in Category Residual-current device | 9 of 28464 |
Colour | Grey |
Exact colour description | Grey |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 1 |
Tripping characteristic | B |
Rated current | 16 A |
Rated current | 0.03 A |
Rated voltage | 230 V |
voltage type | AC |
Rated insulation voltage Ui | 264 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | China |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Siemens fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 77 mm |
Width | 36 mm |
Height | 90 mm |
Weight | 272 g |
Length | 10 cm |
Width | 9 cm |
Height | 5 cm |
Weight | 260 g |
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec GalaxusHow many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec GalaxusUnfortunately, we don't have enough data for this category yet.
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus