Schneider Electric FiCuTor iID
Only 3 pieces in stock at supplier
Rated current2
Product details
Residual current circuit breaker Acti 9 iID, 1.5kA (IEC/EN 61008-1). 4-pole, rated current 80A, earth fault sensitivity 30mA, earth fault protection class Type A, operating voltage (Ue) 400V AC, insulation voltage (Ui) 500V AC. Provides additional protection against direct contact (≤ 30mA). Fault protection against indirect contact, e.g., in case of insulation faults (≥ 100mA, ≤ 300mA). Fault protection in construction site distribution boards (500mA). Switching and isolating circuits. Jump switching for low-wear contact operation. With mechanical front-side fault indication (VisiTrip) to show tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the residual current circuit breaker, with green indication ensuring voltage-free safety on the outgoing side. Test button for regular functional testing. Double connection terminals for connecting cables or phase rails on both sides. Easy removal of the individual device when a phase rail is installed, thanks to the front-accessible fastening element. Additional snap-on auxiliary modules (optional) - undervoltage release (iMN), overvoltage release (iMSU), operating current release (iMX), auxiliary switch for status indication (iOF), fault indication switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards - IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified.
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Length | 44 mm |
Width | 72 mm |
Item number | 12900682 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | A9Z21480 |
Release date | 12.3.2020 |
Colour | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 80 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | France, Spain |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 18.08 kg |
Climate contribution | CHF 0.43 |
Items per sales unit | 1 pcs. |
Length | 44 mm |
Width | 72 mm |
Height | 91 mm |
Weight | 370 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Siemens0 %
- 4.ABB0.1 %
- 4.Schneider Electric0.1 %
- 6.Hager0.2 %
- 7.Steffen0.4 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 2.Steffen0.6 %
- 3.Eaton0.7 %
- 4.Schneider Electric1.3 %
- 5.ABB2.1 %
- 6.Siemens3.4 %