Schneider Electric moulded-case circuit-breaker C10V3TM040 Manufacturer :Schneider Electric Designation :moulded-case circuit-breaker ComPacT NSX100HB1 Type :C10V3TM040 Rated continuous current Iu :40 A Rated voltage :690 V Overload release Current setting :70...100 A Integrated earth fault protection :no Connection type main circuit :Screw connection Device type :Built-in device Fixed installation technology Suitable for top hat rail mounting :no Top hat rail mounting optional :no With trip indicator :no Number of poles :3 Position of connection for main circuit :front Actuator design :Knob Complete device with protection unit :yes Motor-drive unit integrated :no Motor-drive unit optional :yes Protection class (IP) :IP40 Schneider Electric moulded case circuit-breaker C10V3TM040: more details This ComPacT NSX100HB1 is a complete 3P 3d fixed-mounting circuit-breaker designed to optimise space and breaking capacity. It is an optimal choice for all standard and special applications. The breaking capacity (Icu) is 85 kA rms at 500 VAC 50/60 Hz and 75 kA rms at 690 VAC 50/60 Hz. The operating voltage is 690 VAC 50/60 Hz. This product has a thermo-magnetic tripping device (TMD) with a rated output of 40 A. The TMD trip unit offers adjustable thermal overload protection and fixed magnetic protection. This 3-pole version (105 mm x 161 mm x 86 mm) comes with a wide range of optional functions and accessories. It is compliant with international standards (IEC 60947), CCC, EAC and marine specifications. ComPacT NSX100HB1 is part of Schneider Electric's EcoStruxure Power architecture. EAN: 3606482001480.
Circuit breaker type | Circuit breaker |
number of poles | 3 |
Mounting type | Built-in installation |
Item number | 33628277 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | C10V3TM040 |
Release date | 17.5.2023 |
Circuit breaker type | Circuit breaker |
Mounting type | Built-in installation |
Mounting type | Screw fastening |
number of poles | 3 |
Tripping characteristic | Sluggish --- |
Rated current | 40 A |
Rated current | 0.01 A |
Rated voltage | 690 V |
voltage type | AC |
Rated insulation voltage Ui | 690 V |
Residual current (rated differential current) | 100 A |
Protection type (IP code) | IP40 |
Country of origin | Poland |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.1 %
- 5.ABB0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 1.Steffen0.3 %
- 2.Brennenstuhl1.6 %
- 3.Schneider Electric1.7 %
- 4.ABB1.9 %
- 5.Eaton3.3 %