Schneider Electric Circuit breaker NG125N, 2P, 63A, C- 18628
Product details
Acti 9 NG125N circuit-breaker, 25kA (IEC/EN 60947-2). 1-pole, rated current 63A, C characteristic, operating voltage (Ue) 380-415V AC, insulation voltage (Ui) 690V AC. Circuit protection against short-circuit currents. Protection of the circuit against overload currents. Tripping is indicated by the centre position of the switching toggle and by a red mechanical indicator on the front of the device. Test button for checking the tripping mechanism. Feed from above or below. Snap action for low-wear switching of the contacts. Release unit technology - thermomagnetic. Additional stackable auxiliary modules (optional)- indication of switching position, fault tripping, shunt opening release, undervoltage release, overvoltage release. The NG125N circuit-breaker fulfils the following standards- IEC/EN 60947-2. Furthermore, this series is VDE certified.
Circuit breaker type | Circuit breaker |
Width | 3 mm |
mounting style | Top-hat rail |
number of poles | 2 |
Item number | 23347873 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | 18628 |
Release date | 7.12.2022 |
Circuit breaker type | Circuit breaker |
mounting style | Top-hat rail |
number of poles | 2 |
Tripping characteristic | C |
Rated current | 63 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 690 V |
Protection type (IP code) | IP20 |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Width | 3 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.2 %
- 5.ABB0.3 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.ABB1.5 %
- 4.Siemens2.1 %
- 5.Schneider Electric2.3 %
- 6.Eaton4.4 %
- 7.Hager4.5 %