F200 Type B for smooth DC residual currents and operational safety, all-current sensitive, 10 ms short-time delayed, surge current resistant up to 3 kA (5 kA selective version). Residual current protective devices (RCCBs) provide protection for persons and property as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. The residual current circuit breakers of the F200 B series ensure protection against earth faults for sinusoidal alternating currents, pulsating currents, and smooth DC residual currents. They also provide fault protection (protection against indirect contact), additional protection (with I?n = 30 mA), and fire protection (with I?n = 300 mA). They comply with product standards for Type A IEC/EN 61008-1, 61008-2-1, 61543 (VDE 0664 10, 11, 30) and Type B DIN EN 62423 (VDE 0664-40). Their primary application areas are in commercial and industrial settings. The extensive range of accessories provides everything you need for your installation tasks. The RCCB Type B is suitable for non-linear circuits that can generate fault currents with smooth DC residual currents and various (high/low) frequencies. These components are found in electronic devices such as frequency converters. The RCCB Type B has a frequency range of 0...2 kHz for detecting the fault current and offers high system availability.
Circuit breaker type | Fault current circuit breaker |
Length | 69 mm |
Width | 4 mm |
number of poles | 4 |
Item number | 34732159 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 2CSF204892R4630 |
Release date | 17.5.2023 |
Circuit breaker type | Fault current circuit breaker |
number of poles | 4 |
Tripping characteristic | B |
Rated current | 63 A |
Rated current | 0.5 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.50 A |
Protection type (IP code) | IPX2 |
Country of origin | Italy |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 69 mm |
Width | 4 mm |
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec GalaxusHow many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec GalaxusUnfortunately, we don't have enough data for this category yet.
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus