Siemens SIEM RCD circuit breaker
Product details
Siemens Digital Industry Residual Current Circuit Breaker 2-pole 5SV3322-6KK60
Manufacturer: Siemens Digital Industry
Designation: 2-pole Residual Current Circuit Breaker Type A
Type: 5SV3322-6KK60
Number of Poles: 2
Rated Voltage: 230 V
Rated Current: 40 A
Rated Residual Current: 0.03 A
Mounting Type: DIN Rail
Residual Current Type: A
Selective Type: No
Short-time Delay Type: Yes
Short-circuit Strength (Icw): 10 kA
Surge Current Strength: 3 kA
Type of Voltage: AC
With Locking Mechanism: Yes
Frequency: 50/60 Hz
Additional Devices Possible: Yes
Protection Class (IP): IP20
Width in Division Units: 4
Installation Depth: 70 mm
Ambient Temperature During Operation: -25..45 °C
Connectable Conductor Cross-section Multi-stranded: 0.75..35 mm²
Connectable Conductor Cross-section Single-stranded: 0.75..35 mm²
Explosion-proof: No
Siemens Digital Industry Residual Current Circuit Breaker 2-pole 5SV3322-6KK60: Additional Details
Residual Current Circuit Breaker, 2-pole, Type A, In: 25 A, 30 mA, 6 mA DC, Un AC: 230 V, Electric Mobility.
The SENTRON 5SV3 Residual Current Circuit Breakers provide comprehensive protection for people and property against electric shock.
These circuit breakers offer reliable safety during installation thanks to the standard included gripping and touch protection.
With the convenient slider manual operation, you can easily detach the circuit breakers from the DIN rail or busbar assembly without tools.
The data matrix code on the device provides quick access to all technical data in the Siemens Industry Online Support App.
The SENTRON protective switching devices can be expanded with a wide range of functions using the continuous accessories from the system modular kit.
Optimal technology for your safety - exclusively from Siemens.
EAN: 4001869600963.
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 2 |
Item number | 33686679 |
Manufacturer | Siemens |
Category | Residual-current device |
Manufacturer no. | 5SV33226KK60 |
Release date | 17.5.2023 |
Circuit breaker type | Fault current circuit breaker |
Mounting type | Top-hat rail |
number of poles | 2 |
Rated current | 40 A |
Rated voltage | 230 V |
voltage type | AC |
Residual current (rated differential current) | 0.03 A |
Protection type (IP code) | IP20 |
Country of origin | Germany |
Manufacturer commitment | RE100, SBTi |
CO₂ emissions | 18.08 kg |
Climate contribution | CHF 0.43 |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Siemens0 %
- 4.ABB0.1 %
- 4.Schneider Electric0.1 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- SiemensNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Eaton0.7 %
- 4.Schneider Electric1.3 %
- 5.ABB2.2 %
- 6.Siemens3.4 %
- 7.Hager5.2 %