Schneider Electric Circuit Breaker 18638

Manufacturer: Schneider Electric
Designation: Circuit Breaker 50A C 3p NG125N
Type: 18638
Installation Depth: 47 mm
Tripping Characteristic: C
Number of Poles (total): 3
Number of Protected Poles: 3
Rated Current: 50 A
Rated Voltage: 400 V
Rated Insulation Voltage Ui: 690 V
Rated Impulse Voltage Uimp: 8 kV
Voltage Type: AC/DC
Rated Breaking Capacity Icu according to IEC 60947-2 at 230 V: 50 kA
Rated Breaking Capacity Icu according to IEC 60947-2 at 400 V: 25 kA
Frequency: 50..60 Hz
Flush Mounting: no
Switching Neutral Conductor: no
Overvoltage Category: 4
Degree of Pollution: 3
Additional Devices Possible: yes
Width in Modular Units: 4.5
Protection Class (IP): IP20
Ambient Temperature during Operation: -30..70 °C
Connectable Conductor Cross-Section Multi-Wire: 1..35 mm²
Connectable Conductor Cross-Section Single-Wire: 1.5..50 mm²
Explosion Protected: no

Schneider Electric Circuit Breaker 18638: additional details
Acti 9 NG125N circuit breaker, 25kA (IEC/EN 60947-2). 2-pole, rated current 50A, C characteristic, operating voltage (Ue) 380-415V AC, insulation voltage (Ui) 690V AC. Protects the circuit against short-circuit currents. Protects the circuit against overload currents. The tripping is indicated by the central position of the switch lever and by a red mechanical display on the front of the device. Test button to check the tripping mechanism. Top or bottom feed. Jump switching for low-wear contact switching. Tripping unit technology: thermomagnetic. Additional attachable auxiliary modules (optional): display of switching position, fault tripping, operational current tripping, undervoltage tripping, overvoltage tripping. The NG125N circuit breaker complies with the following standards: IEC/EN 60947-2. Furthermore, this series is VDE certified. EAN: 3303430186380.

Key specifications

Circuit breaker type
Circuit breaker
Length
47 mm
Width
4.50 mm
mounting style
Flush-mounted
number of poles
3
Item number
32174884

General information

Manufacturer
Schneider Electric
Category
Residual-current device
Manufacturer no.
18638
Release date
16.11.2022

Circuit Breaker Features

Circuit breaker type
Circuit breaker
mounting style
Flush-mounted
number of poles
3
Tripping characteristic
C
Rated voltage
400 V
voltage type
AC/DC
Rated insulation voltage Ui
690 V
Protection type (IP code)
IP20

Origin

Country of origin
France

Sustainability

Manufacturer commitment
RE100SBTi

Voluntary climate contribution

Manufacturer compensation
According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions.
CO₂-Emission
Climate contribution

Scope of delivery

Items per sales unit
1 Piece

Product dimensions

Length
47 mm
Width
4.50 mm

30-day right of return if unopened
24 Months Warranty (Bring-in)

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Brennenstuhl
    0 %
  • 1.Schneider Electric
    0 %
  • 1.Siemens
    0 %
  • 4.Eaton
    0.2 %
  • 5.ABB
    0.3 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data
  • Legrand
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 1.Steffen
    0.3 %
  • 2.Brennenstuhl
    1.5 %
  • 3.Schneider Electric
    1.6 %
  • 4.Legrand
    2 %
  • 4.Siemens
    2 %
Source: Digitec Galaxus