Schneider Electric M9F23332 M9 C60SP 3P 32A D UL1077 LS switch
Product details
C60BP Multi 9 OEM Circuit Breaker, 10 kA. Single-pole, rated current 20 A, Z-characteristic, operating voltage (Ue) 240 V AC IEC/EN 60947-2 / 277 V AC UL 489, insulation voltage (Ui) 500 V AC. Simple connection terminal for cables and pin busbar on the top and bottom of the device. Mounting via standard clip closure on DIN rail. Snap action for low-wear switching of contacts. Additional attachable auxiliary modules (optional) - indication of switching position (OF), fault tripping (SD), working current tripping (MX, MX+OF), undervoltage tripping (MN, MNs, MNx). Tool-free mounting on the left side of the device. The C60SP complies with the following standards: IEC/EN 60947-2, UL 489 / CSA C22.2 No. 5 / GB 14048-2. C60SP circuit breakers are multi-standard circuit breakers that can be used worldwide, as they meet all international and all major national standards.
Circuit breaker type | Miniature circuit breaker |
Width | 6 mm |
mounting style | Top-hat rail |
number of poles | 3 |
Item number | 31995936 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | M9F23332 |
Release date | 24.10.2022 |
Circuit breaker type | Miniature circuit breaker |
mounting style | Top-hat rail |
number of poles | 3 |
Tripping characteristic | D |
Rated current | 32 A |
voltage type | AC |
Rated insulation voltage Ui | 500 V |
Protection type (IP code) | IP20 |
Country of origin | France |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Width | 6 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.2 %
- 5.ABB0.3 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- LegrandNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 1.Steffen0.3 %
- 2.Brennenstuhl1.5 %
- 3.Schneider Electric1.6 %
- 4.Legrand2 %
- 4.Siemens2 %