Product details
Residual current circuit breaker Acti 9 iID, 1.5 kA (IEC/EN 61008-1). 4-pole, rated current 80 A, earth fault sensitivity 300 mA, earth fault protection class type A, selective, operating voltage (Ue) 400 V AC, insulation voltage (Ui) 500 V AC. Provides additional protection against direct contact (≤ 30 mA). Fault protection against indirect contact, e.g., in case of insulation faults (≥ 100 mA, ≤ 300 mA). Fault protection in construction site distribution boards (500 mA). Switching and disconnecting circuits. Jump switching for low-wear contact operation. With mechanical front-side fault indication (VisiTrip) to display tripping due to overload or short circuit. Safe contact indication (VisiSafe) of the residual current circuit breaker, with green indication ensuring voltage-free safety on the outgoing side. Test button for regular functional testing. Double connection terminals for both-sided connection of cables or phase rails. Easy removal of the individual device when a phase rail is installed, thanks to the front-accessible fastening element. Selective version to ensure correct differentiation between the various residual current devices and the tripping of the device closest to the fault. Additional attachable auxiliary modules (optional): undervoltage release (iMN), overvoltage release (iMSU), working current release (iMX), auxiliary switch for status reporting (iOF), fault reporting switch (iSD). Tool-free mounting on the left side of the device. Color shade RAL 9003. The residual current circuit breaker iID complies with the following standards: IEC/EN 61008-1 and IEC/EN 60947-2. Furthermore, this series is VDE certified.
Circuit breaker type | Fault current circuit breaker |
Length | 44 mm |
Width | 72 mm |
mounting style | Top-hat rail |
number of poles | 4 |
Item number | 12900694 |
Manufacturer | Schneider Electric |
Category | Residual-current device |
Manufacturer no. | A9Z25480 |
Release date | 12.3.2020 |
External links |
Colour | White |
Exact colour description | White |
Circuit breaker type | Fault current circuit breaker |
mounting style | Top-hat rail |
number of poles | 4 |
Tripping characteristic | A |
Rated current | 80 A |
Rated voltage | 400 V |
voltage type | AC/DC |
Rated insulation voltage Ui | 500 V |
Residual current (rated differential current) | 0.30 A |
Protection type (IP code) | IP20 |
Country of origin | Spain |
Manufacturer commitment | RE100, SBTi |
Manufacturer compensation | According to RE100, the manufacturer Schneider Electric fully compensates for its energy consumption, leading to a reduction in emissions. |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 44 mm |
Width | 72 mm |
Height | 91 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.1 %
- 5.Hager0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- Schneider ElectricNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 2.ABB1.6 %
- 2.Brennenstuhl1.6 %
- 2.Schneider Electric1.6 %
- 5.Siemens2.1 %
- 6.Eaton4 %