Schneider EasyPact CVS160F circuit-breaker, 36 kA at 415 VAC, 4P 3d, TM-D 125 A trip unit LV516342
Product details
The EasyPact CVS160F is a 4-pole circuit breaker designed for fixed installation, offering high performance and cost-effective functionality. It is the optimized choice for protecting small and medium-sized buildings. The breaking capacity (Icu) is 36 kA rms at 415 VAC 50/60 Hz. The operating voltage is 440 VAC 50/60 Hz. This product features an integrated thermal-magnetic release (TMD) with a rated current of 125 A. The TMD release provides adjustable thermal overload protection and fixed magnetic protection. This 4-pole variant (140 mm x 161 mm x 86 mm) can be equipped with a variety of optional functions and accessories. The EasyPact CVS160F complies with international standards (IEC 60947, CCC, EAC). It can be installed in Class II insulating material distribution boards, as it is a front-mounted device of Class II (IEC 60664-1).
Circuit breaker type | Circuit breaker |
Mounting type | Built-in installation |
number of poles | 4 |
Length | 140 mm |
Width | 161 mm |
Item number | 47141984 |
Manufacturer | Schneider |
Category | Residual-current device |
Manufacturer no. | LV516342 |
Release date | 10.7.2024 |
Circuit breaker type | Circuit breaker |
Mounting type | Built-in installation |
Mounting type | Screw fastening |
number of poles | 4 |
Rated current | 125 A |
Rated voltage | 440 V |
voltage type | AC |
Protection type (IP code) | IP40 |
Country of origin | Indonesia |
Items per sales unit | 1 pcs. |
Length | 140 mm |
Width | 161 mm |
Height | 86 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- SchneiderNot enough data
- 1.Brennenstuhl0 %
- 1.Eaton0 %
- 1.Siemens0 %
- 4.ABB0.1 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- SchneiderNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- SchneiderNot enough data
- 1.Max Hauri0.4 %
- 2.Steffen0.6 %
- 3.Eaton0.7 %
- 4.Schneider Electric1.3 %