Hager NCN316. Number of poles: 3P. AC input frequency: 50/60 Hz, Nominal current output: 16 A.
Only 2 pieces in stock at supplier
Product details
Hager Circuit Breaker NCN316
Manufacturer: Hager
Designation: 3-pole circuit breaker, C-16A, 10kA, 3M
Type: NCN316
Installation depth: 70 mm
Tripping characteristic: C
Number of poles (total): 3
Number of protected poles: 3
Rated current: 16 A
Rated voltage: 400 V
Rated insulation voltage Ui: 500 V
Rated impulse voltage withstand Uimp: 6 kV
Rated breaking capacity Icn according to EN 60898 at 230 V: 10 kA
Type of voltage: AC
Rated breaking capacity Icn according to EN 60898 at 400 V: 10 kA
Rated breaking capacity Icu according to IEC 60947-2 at 230 V: 30 kA
Rated breaking capacity Icu according to IEC 60947-2 at 400 V: 15 kA
Frequency: 50-60 Hz
Power loss: 8.27 W
Energy limiting class: 3
Flush mounting: yes
Switching neutral conductor: no
Overvoltage category: 3
Degree of pollution: 2
Additional devices possible: yes
Width in modular units: 3
Protection class (IP): IP20
Ambient temperature during operation: -25 to 70 °C
Connectable conductor cross-section multi-stranded: 1 to 25 mm²
Connectable conductor cross-section single-stranded: 1 to 35 mm²
Explosion-proof: no
Hager Circuit Breaker NCN316: further details
3-pole circuit breaker 10kA/15kA C-16A 3M. Circuit breaker according to DIN EN 60898-1 (VDE 0641-11) with time-delayed thermal tripping for overload protection and electromagnetic tripping for short-circuit protection. Suitable for retrofitting additional devices. Labeling option directly on the device and individual removal from the phase rail connection by releasing the DIN rail quick fastening.
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 3 |
Length | 70 mm |
Width | 53 mm |
Item number | 17934155 |
Manufacturer | Hager |
Category | Residual-current device |
Manufacturer no. | NCN316 |
Release date | 16.12.2021 |
External links |
Colour | Grey |
Exact colour description | Grey |
Circuit breaker type | Miniature circuit breaker |
Mounting type | Top-hat rail |
number of poles | 3 |
Tripping characteristic | C |
Rated current | 16 A |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 500 V |
Protection type (IP code) | IP20 |
Country of origin | China |
CO₂ emissions | 36.84 kg |
Climate contribution | CHF 0.88 |
Items per sales unit | 1 pcs. |
Length | 70 mm |
Width | 53 mm |
Height | 83 mm |
Weight | 350 g |
Length | 9.30 cm |
Width | 7.30 cm |
Height | 5.40 cm |
Weight | 321 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Siemens0 %
- 4.ABB0.1 %
- 4.Schneider Electric0.1 %
- 6.Hager0.2 %
- 7.Steffen0.4 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- HagerNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Eaton0.7 %
- 4.Schneider Electric1.3 %
- 5.ABB2.2 %
- 6.Siemens3.4 %
- 7.Hager5.2 %