Doepke DFS2 025-2/0.03-A KV

Delivered between Tue, 27.5. and Wed, 28.5.
More than 10 items in stock at third-party supplier
Supplied by

Product details

Residual Current Circuit Breakers (RCCB) disconnect the power supply when dangerously high fault currents occur, thereby protecting people, animals, and equipment. DFS 2 are two-pole residual current circuit breakers for single-phase networks. The large double-deck terminals can accommodate large conductor cross-sections. The tripped position of the multifunction switch knob facilitates troubleshooting. Type A switches are sensitive to pulsating and alternating currents. This function is independent of the mains voltage. Residual current circuit breakers in KV version (KV for short-time delayed) are significantly less sensitive to short-term impulse-like surge and fault currents, thus increasing the availability of the system. The additional protection (personal protection) is maintained. The short-time delayed switches can therefore be easily used in place of a standard switch.

Features:

  • Pulsating and alternating current sensitive, independent of mains voltage
  • High immunity to surge fault currents and mains voltage-driven follow current impulses
  • Low power loss per pole
  • VDE certified
  • Mains and auxiliary voltage independent tripping
  • Sensitive to alternating and pulsating direct fault currents (Type A)
  • Compact size for all rated currents
  • High short-circuit resistance
  • Double-deck terminals on both sides for large conductor cross-sections and rail connection
  • Switching position indicator
  • Viewing window for labeling stickers
  • Multifunction switch knob with three positions: On - Off - Tripped
  • Neutral conductor position adjustable
  • Quick mounting on mounting rail, installation position adjustable, feed direction adjustable

Technical Data:
Version: short-time delayed
Fault current type: A
Rated fault current: 0.03 A
Number of poles: 2
Rated current: 25 A.

Key specifications

Circuit breaker type
Fault current circuit breaker
mounting style
Top-hat rail
number of poles
2
Item number
22863267

General information

Manufacturer
Doepke
Category
Residual-current device
Manufacturer no.
09124609
Release date
27.10.2022

Circuit Breaker Features

Circuit breaker type
Fault current circuit breaker
mounting style
Top-hat rail
number of poles
2
Tripping characteristic
A
Rated current
25 A
Rated current
0.03 A
Rated voltage
230 V
voltage type
AC
Rated insulation voltage Ui
400 V
Residual current (rated differential current)
0.03 A
Protection type (IP code)
IP20

Origin

Country of origin
Germany

Voluntary climate contribution

CO₂-Emission
Climate contribution

Scope of delivery

Items per sales unit
1 Piece

30-day right of return if unopened
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Brennenstuhl
    0 %
  • 1.Schneider Electric
    0 %
  • 1.Siemens
    0 %
  • 4.Eaton
    0.2 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • Doepke
    Not enough data
  • 1.Steffen
    0.3 %
  • 2.ABB
    1.4 %
  • 2.Brennenstuhl
    1.4 %
  • 4.Siemens
    2 %
Source: Digitec Galaxus