Ceag Ex motor protection switch
Product details
Ceag safety motor-protective circuit-breaker GHG 635 1101 R0111. Manufacturer: Ceag Sicherheitst. Designation: Ex motor-protective circuit-breaker 9.0A-12.5A. Type: GHG 635 1101 R0111. Overload release current setting: 9-12.5 A. Setting range of the instantaneous short-circuit release: 9-12.5 A. With thermal protection: Yes. Phase failure sensitive: Yes. Tripping technology: Thermomagnetic. Rated operating voltage: 400 V. Rated continuous current Iu: 12.5 A. Rated operating power at AC-3, 230 V: 3.18 kW. Rated operating power at AC-3, 400 V: 5.5 kW. Connection type main circuit: Screw connection. Type of actuating element: Pushbutton. Device type: Other. With integrated auxiliary switch: Yes. With integrated undervoltage release: Yes. Number of poles: 5. Rated short-circuit breaking current Icu at 400 V, AC: 50 kA. Protection class (IP): IP66. Height: 225 mm. Width: 140 mm. Depth: 156 mm. Further details: Ex motor-protective circuit-breaker standard (without cable) 25 A for Zone 1/2, 9.0 A - 12.5 A, without UVR, cable entries: 2 x M32, polyamide, EAN: 4250217428760.
Circuit breaker type | Motor protection switch |
Length | 156 mm |
Width | 140 mm |
number of poles | 5 |
Item number | 36750060 |
Manufacturer | Ceag |
Category | Residual-current device |
Manufacturer no. | GHG6351101R0111 |
Release date | 28.6.2023 |
Circuit breaker type | Motor protection switch |
number of poles | 5 |
Tripping characteristic | Sluggish --- |
Rated voltage | 400 V |
voltage type | AC |
Rated insulation voltage Ui | 400 V |
Protection type (IP code) | IP66 |
Country of origin | Germany |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 156 mm |
Width | 140 mm |
Height | 225 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- CeagNot enough data
- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- CeagNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- CeagNot enough data
- 1.Steffen0.3 %
- 2.Brennenstuhl1.5 %
- 3.Schneider Electric1.6 %
- 4.Legrand2 %