Busch-Jaeger Busch-Jäger DS204A-B16/0,03 FI/LS combination 6kA,4P,type A,B 16A,30mA DS204 A-B16/0,03
Product details
ABB Stotz S&J RCD/MCB Switch DS204A-B16/0.03
Manufacturer: ABB Stotz S&J
Designation: RCD/MCB Switch
Type: DS204A-B16/0.03
Rated Current: 16 A
Rated Residual Current: 30 mA
Number of Protected Poles: 4
Switching Neutral Conductor: No
Tripping Characteristic: B
Breaking Capacity: 6 kA
Number of RCD/MCB Combinations: 1
Wiring on Terminal Block: No
Height: 93 mm
Width: 105 mm
Depth: 69 mm
Further Details: RCD/MCB combinations (RCBOs) provide personal and property protection as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection for 1P+N, 2P, 3P+N, or 4P circuits against overload and short-circuit currents, protection against sinusoidal alternating currents and pulsating currents with a smooth DC residual current component of up to 6 mA to earth. They also provide fault protection (protection against indirect contact), additional protection (with I?n = 30 mA), and fire protection (with I?n = 300 mA). They comply with the product standard IEC/EN 61009-1 (VDE 0664-20).
Areas of application include household, commercial, and industrial applications. The extensive range of accessories provides everything you need for your installation tasks. Numerous approvals make the DS200 suitable for worldwide use. Rated breaking capacity Icn = 6,000 A according to IEC/EN 61009-1 (VDE 0664-20) for RCDs (Residual Current Devices) in residential construction and similar applications, Icu = 10 kA according to IEC/EN 60947-2 (VDE 0660-101) for MCBs (MCB) in industrial applications. RCBO DS200 Type A is 2-/4-pole protected (MCB), 2-/4-pole switching. EAN: 8012542859802.
Circuit breaker type | Fault current circuit breaker |
Length | 69 mm |
Width | 105 mm |
mounting style | Top-hat rail |
number of poles | 4 |
Item number | 32014608 |
Manufacturer | Busch-Jaeger |
Category | Residual-current device |
Manufacturer no. | 2CSR254101R1165 |
Release date | 29.10.2022 |
Colour | Grey |
Exact colour description | Grey |
Circuit breaker type | Fault current circuit breaker |
mounting style | Top-hat rail |
number of poles | 4 |
Tripping characteristic | B |
Rated current | 16 A |
Rated voltage | 400 V |
Rated insulation voltage Ui | 400 V |
Residual current (rated differential current) | 0.03 A |
Country of origin | Italy |
CO₂-Emission | |
Climate contribution |
Items per sales unit | 1 Piece |
Length | 69 mm |
Width | 105 mm |
Height | 93 mm |
Weight | 780 g |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- Busch-JaegerNot enough data
- 1.Brennenstuhl0 %
- 1.Schneider Electric0 %
- 1.Siemens0 %
- 4.Eaton0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- Busch-JaegerNot enough data
- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- Busch-JaegerNot enough data
- 1.Steffen0.4 %
- 2.Brennenstuhl1.4 %
- 3.ABB1.8 %
- 3.Legrand1.8 %