ABB Motor protection switch MS116 - 6.3
More than 10 pieces in stock at third-party supplier
Product details
Motor starter type = Direct starter
Operating voltage = 690 V ac
Protection class = IP20
Phase = 1, 3
Number of poles = 3P
Motor starter mode of operation = Manual
Total length = 90mm
Housing = Yes
Total width = 45mm
Total depth = 80.1mm
Series = MS116
UL, CSA, ship approvals. MS 116 - Motor Protective Circuit Breaker. Economical fuseless protection for drives up to 7.5kW Thermal and electromagnetic tripping Lockable, can be used as disconnector (to IEC/EN 60947-1) Short-circuit proof up to 50 kA With phase loss sensitivity Temperature compensated Clear switch position indication by modern rotary handle movement Low storage costs, only 11 current ranges up to 16 A Construction width 45mm. Accessories:. HKF1 - Auxiliary switch front mounting HK1 - Auxiliary switch side mounting right SK1 - Signal contact for general tripping indication, side mounting right IB116 - Insulated enclosure IP65 QES 4/3N - Insulated enclosure IP55 SMO 4 - Collecting terminal for N or PE, for enclosure QES 4//3 N UA1-230- Undervoltage release, side mounting left.
Circuit breaker type | Motor protection switch |
number of poles | 3 |
Length | 95 mm |
Width | 45 mm |
Item number | 9727301 |
Manufacturer | ABB |
Category | Residual-current device |
Manufacturer no. | 1SAM250000R1009 |
Release date | 24.9.2018 |
Circuit breaker type | Motor protection switch |
number of poles | 3 |
Rated voltage | 690 V |
voltage type | AC/DC |
Protection type (IP code) | IP20 |
Country of origin | China |
Manufacturer commitment | SBTi |
CO₂ emissions | 18.08 kg |
Climate contribution | CHF 0.43 |
Items per sales unit | 1 pcs. |
Length | 95 mm |
Width | 45 mm |
Height | 90 mm |
Compare products
Goes with
Reviews & Ratings
Warranty score
How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?
Source: Digitec Galaxus- 1.Eaton0 %
- 1.Siemens0 %
- 4.ABB0.1 %
- 4.Schneider Electric0.1 %
- 6.Hager0.2 %
Warranty case duration
How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?
Source: Digitec Galaxus- ABBNot enough data
- BrennenstuhlNot enough data
- EatonNot enough data
- HagerNot enough data
- Max HauriNot enough data
Unfortunately, we don't have enough data for this category yet.
Return rate
How often is a product of this brand in the «Residual-current device» category returned?
Source: Digitec Galaxus- 3.Eaton0.7 %
- 4.Schneider Electric1.3 %
- 5.ABB2.2 %
- 6.Siemens3.4 %
- 7.Hager5.2 %