ABB Ground fault circuit interrupter block 4 pole 40A 300mA

Delivered Wed, 25.6.
Only 4 items in stock at third-party supplier
Supplied by
free shipping

Product details

ABB Stotz S&J RCD Block DDA204A-40/0.3

Manufacturer: ABB Stotz S&J
Designation: RCD Block 4p, 40A, 300mA
Type: DDA204A-40/0.3
Rated Voltage: 230..400 V
Rated Current: 40 A
Adjustable Rated Residual Current: no
Rated Residual Current: 0.3 A
Max. Delay Time: 0 ms
Adjustable Delay Time: no
Number of Poles: 4
Residual Current Type: A
Frequency: 50/60 Hz
Rated Insulation Voltage Ui: 500 V
Rated Impulse Voltage Uimp: 4 kV
Connectable Conductor Cross-Section Single Wire: 16 mm²
Connectable Conductor Cross-Section Multi-Wire: 16 mm²
False Tripping Protection: no
With Locking Mechanism: yes
Protection Class (IP): IP2X
Ambient Temperature During Operation: -25..55 °C

The RCD block (RCU) is designed for customer-side installation with circuit breakers of the S200 series. The resulting RCD/MCB combination (RCBOs) provides protection for persons and property as well as protection against electrically ignited fires in accordance with DIN VDE 0100-410 and DIN VDE 0100-530. They ensure protection for 1P+N, 2P, 3P, 3P+N, or 4P circuits against overload and short-circuit currents, protection for sinusoidal alternating currents and pulsating currents with a smooth DC fault current component of up to 6 mA to earth. Additionally, they provide fault protection (protection against indirect contact), supplementary protection (with I?n = 30 mA), and fire protection (with I?n = 300 mA). They comply with the product standard IEC/EN 61009 Annex G. Application areas include household, commercial, and industrial applications. The extensive range of accessories provides everything you need for your installation tasks. The rated short-circuit capacity is 6 kA for S200 MCBs, 10 kA for S200 M, and 25 kA for S200 P.

Key specifications

Circuit breaker type
Residual current protection block
mounting style
Top-hat rail
number of poles
4
Item number
9717670

General information

Manufacturer
ABB
Category
Residual-current device
Manufacturer no.
2CSB204101R3400 - DDA204A-40/0,3
Release date
24.9.2018
External links

Circuit Breaker Features

Circuit breaker type
Residual current protection block
mounting style
Top-hat rail
number of poles
4
Tripping characteristic
A
Rated current
40 A
Rated current
0.3 A
Rated voltage
400 V
voltage type
AC/DC
Rated insulation voltage Ui
500 V
Residual current (rated differential current)
0.30 A
Protection type (IP code)
IPX2

Origin

Country of origin
Italy

Sustainability

Manufacturer commitment
SBTi

Voluntary climate contribution

CO₂-Emission
Climate contribution

Scope of delivery

Items per sales unit
1 Piece

30-day right of return if unopened
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Siemens
    0 %
  • 4.Eaton
    0.2 %
  • 5.ABB
    0.3 %
  • 5.Hager
    0.3 %
  • 7.Steffen
    0.6 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data
  • Legrand
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 1.Steffen
    0.4 %
  • 2.Brennenstuhl
    1.4 %
  • 3.ABB
    1.7 %
  • 4.Legrand
    1.8 %
  • 4.Schneider Electric
    1.8 %
Source: Digitec Galaxus