ABB Ground fault circuit interrupter block 3-pole 40A 30mA

Delivered between Tue, 7.4. and Fri, 10.4.
Only 2 pieces in stock at third-party supplier
Supplied by
free shipping

Product details

Number of poles: 3P
Rated current: 40A
Trip sensitivity: 30mA
AC rated voltage: 415 V
Mounting type: DIN rail mounting
Range: pro M compact
Series: DDA 200 A

IEC/EN 61009 RCD circuit breaker blocks, DDA 200A series. With integrated connection rail for right-flush mounting of 2-, 3- and 4-pole miniature circuit breakers of the S200 series. Neutral conductor connection can be made on the right or left. Application areas include escalators, elevators, electrically operated gates and barriers, machine tools, car washes, and conveyor belts.

Key specifications

Circuit breaker type
Residual current protection block
Mounting type
Top-hat rail
number of poles
3

General information

Item number
9717681
Manufacturer
ABB
Category
Residual-current device
Manufacturer no.
2CSB203101R1400 - DDA203A-40/0,03
Release date
24.9.2018

Circuit Breaker Features

Circuit breaker type
Residual current protection block
Mounting type
Top-hat rail
number of poles
3
Tripping characteristic
A
Rated current
40 A
Rated current
0.03 A
Rated voltage
400 V
voltage type
AC/DC
Rated insulation voltage Ui
40 V
Residual current (rated differential current)
0.03 A

Origin

Country of origin
Italy

Sustainability

Manufacturer commitment
SBTi

Voluntary climate contribution

CO₂ emissions
18.08 kg
Climate contribution
CHF 0.43

Scope of delivery

Items per sales unit
1 pcs.

30-day right of return
24 Months Warranty (Bring-in)
1 additional offer

Compare products

Goes with

Reviews & Ratings

Warranty score

How often does a product of this brand in the «Residual-current device» category have a defect within the first 24 months?

Source: Digitec Galaxus
  • 1.Eaton
    0 %
  • 1.Siemens
    0 %
  • 4.ABB
    0.1 %
  • 4.Schneider Electric
    0.1 %
  • 6.Hager
    0.2 %

Warranty case duration

How many working days on average does it take to process a warranty claim from when it arrives at the service centre until it’s back with the customer?

Source: Digitec Galaxus
  • ABB
    Not enough data
  • Brennenstuhl
    Not enough data
  • Eaton
    Not enough data
  • Hager
    Not enough data
  • Max Hauri
    Not enough data

Unfortunately, we don't have enough data for this category yet.

Return rate

How often is a product of this brand in the «Residual-current device» category returned?

Source: Digitec Galaxus
  • 3.Eaton
    0.7 %
  • 4.Schneider Electric
    1.3 %
  • 5.ABB
    2.2 %
  • 6.Siemens
    3.4 %
  • 7.Hager
    5.2 %
Source: Digitec Galaxus